BAM una et tria tempus Power Capacitor

Description:

。 Rated intentione: 6.3kV, 6.6kV, 6.6/√3kV, 7.96kV, 10.5kV, 11kV, 11kV, 11/√3kV, quaeso ordine significari, si alteram facultatem specialem vis.
。 Rated capacitas: 33~334kvar placet ordine indicata si vis alteram capacitatem specialem.
。 Capacitas tolerantiae: -5 ~ 15%.
。 Angelum damnum tangentialem valorem: film & papaer medium tg θ≦0.08%, film medium tg θ≦0.05%.

Product Detail

Product Tags

BAM High intentione Power Capacitor

Applicationes et signa:

Capacitas alta intentione in AC potentiae ratio maxime adhibetur cum 50Hz ad factorem potentiae emendandum. Effectus conformis est GB 3083.2-89 - Princeps intentionis shunt capacitor》 et IEC 60871-1987.

GB/T11024-2010 National vexillum 《Rated intentione 1kV vel supra shunt capacitors pro AC potentia systemata

JB/7112-2000 Machinery vexillum Industry Asembled HV Shunt Capacitor

DL/T628-1997 Electric Power Industry vexillum Assembled HV Shunt Capacitor Ordinis Technical opus est

Condiciones Ritus:

1.Altitude: minus quam 1000m; Ambiens Temperature: -40℃ ~ +40℃。

2. Nulla vibratio mechanica violenta, nulla gas et vapor nociva, nulla electrica, explosiva, pulvis explosivus in locatione.

3.Continuosa operatio voltage: 1.00 Un, longum tempus max, Plus intentione: less.1 Un.

4.Stable plus-curens (including harmonica current) minus 1.3 In.

5. With sta intentione: inter terminales 2.15, tempus aestimatur intentione pro 10 secundis, inter terminales et continens 42kV pro 10 secundis.

Praecipua technicae notae:

1.Rated intentione: 6.3kV, 6.6kV, 6.6/√3kV, 7.96kV, 10.5kV, 11kV, 11kV, 11/√3kV, quaeso ordine significari, si alteram facultatem specialem vis.

2. Rated capacitas: 33~334kvar placet ordine indicata si vis alteram capacitatem specialem.

3. Capacitas tolerantiae: -5 ~ 15%.

4. Angelus pretii tangentialis amissus: film & papaer medium tg θ≦0.08%, film medium tg θ≦0.05%.

5. Withstand intentione: potest AC2.15 vel DC4.3 temporibus intentionem aestimatam inter capacitatem pallidam praestare, postrema circiter 10* sine intermissione vel mico, BIL: 6kV(30kV), 10kV(42Kv).

6. Liberum missionem: habet resistentiam interiorem, 10 min, post abscissam potestatem supplendi, residua intentione ad 75V ab √2 Un redibit.

7.Max. Current: nonumy sub 1.3 tempore, intentione aestimata, per intentionem, capacitatem tolerantiae positivi et undae harmonicae quae singulas 24 horas non potest excedere.

8.Max.Current: nonumy sub 1.3 tempore aestimata intentione, per intentionem, capacitatem tolerantiae positivae et fluctum harmonicam quae non potest 1.43 tempus currenti aestimavit.

9.Standard: GB/T 112024.1-2001, IEC6087:1997.

rth *

Separate Phase Power Capacitor

Exemplar BAM Rated Voltage (kV) Rated Output (kVAr) Rated Capacitance (uF) Current Rated in (A)
10.5-50-1W 10.5 50 1.444 4.762
6.35-30-1W 6.35 30 2.368 4.724
6.35-50-1W 6.35 50 3.946 7.873
6.3-30-1W 6.3 30 2.4 4.76
6.3-50-1W 6.3 50 4 7.9
6.3-100-1W 6.3 100 8 15.9
6.3-200-1W 6.3 200 16 31.7
6.3300-1W 6.3 300 XXIV 47.6
6.3-334-1W 6.3 334 26.8 53
10.5-50-1W 10.5 50 1.44 4.8
10.5-100-1W 10.5 100 2.9 9.5
10.5-150-1W 10.5 150 4.3 14.3
10.5-200-1W 10.5 200 5.8 19
10.5-300-1W 10.5 300 8.67 28.6
10.5-334-1W 10.5 334 9.65 31.8
6.35-50-1W 6.35 50 3.95 7.87
6.35-100-1W 6.35 100 7.89 15.75
6.35-150-1W 6.35 150 11.84 23.6
6.35-200-1W 6.35 200 15.78 31.5
6.35-300-1W 6.35 300 23.68 47.2
6.35-334-1W 6.35 334 26.36 52.6
3.81-50-1W 3.81 50 10.96 13.12
3.81-100-1W 3.81 100 21.9 26.24
3.81-150-1W 3.81 150 32.9 39.36
3.81-200-1W 3.81 200 43.8 52.48
3.81-300-1W 3.81 300 65.8 78.7
3.81-334-1W 3.81 334 73.2 87.6
11-100-1W 11 100 2.63 9.1
11-150-1W 11 150 3.95 13.6
11-200-1W 11 200 5.26 18.2
11-300-1W 11 300 7.89 27.3
11-334-1W 11 334 8.79 30.4
12-100-1W 12 100 2.2 8.33
12-150-1W 12 150 3.3 12.5
12-200-1W 12 200 4.4 16.7
12-300-1W 12 300 6.64 25
12-334-1W 12 334 7.39 27.8
6.93-100-1W 6.93 100 6.63 14.4
6.93-150-1W 6.93 150 9.95 21.7
6.93-200-1W 6.93 200 13.3 28.9
6.93-300-1W 6.93 300 19.9 43.3
6.93-334-1W 6.93 334 22.1 48.2
6.93-400-1W 6.93 400 26.54 57.74
6.3-100-1W 6.3 100 8 15.9
6.3-150-1W 6.3 150 12 23.8
6.3-200-1W 6.3 200 16 31.7
6.3300-1W 6.3 300 XXIV 47.6
6.3-334-1W 6.3 334 26.8 53
6.6-100-1W 6.6 100 7.3 15.2
6.6-150-1W 6.6 150 11 22.7
6.6-200-1W 6.6 200 14.6 30.3
6.6-300-1W 6.6 300 vigintiduo 45.5
6.6-334-1W 6.6 334 24.4 50.6
3.81-100-1W 3.81 100 21.9 26.24
3.81-150-1W 3.81 150 32.9 39.36
3.81-200-1W 3.81 200 43.8 52.48
3.81-300-1W 3.81 300 65.8 78.7
3.81-334-1W 3.81 334 73.2 87.6
6.35-100-1W 6.35 100 7.89 15.75
6.35-150-1W 6.35 150 11.84 23.6
6.35-200-1W 6.35 200 15.78 31.5
6.35-300-1W 6.35 300 23.68 47.2
6.35-334-1W 6.35 334 26.36 52.6
11-100-1W 11 100 2.63 5.25
11-150-1W 11 150 3.95 7.87
11-200-1W 11 200 5.26 10.5
11-300-1W 11 300 7.9 15.75
11-100-1W 11 100 2.63 5.25
11-150-1W 11 150 3.95 7.87
11-200-1W 11 200 5.26 10.5
11-300-1W 11 300 7.9 15.75
12-100-1W 12 100 2.2 4.8
12-150-1W 12 150 3.3 7.2
12-200-1W 12 200 4.4 9.6
12-300-1W 12 300 6.64 14.45
12-100-1W 12 100 2.2 4.8
12-150-1W 12 150 3.2 7.2
12-200-1W 12 200 4.4 9.6
12-300-1W 12 300 6.64 14.45
11/√3-200-1W 11/√3 200 15.78 31.5
11/√3-334-1W 11/√3 334 26.36 52.6
12/√3-200-1W 12/√3 200 13.3 28.9
12/√3-334-1W 12/√3 334 22.1 48.2
12-200-1W 12 200 4.4 16.7
12-334-1W 12 334 7.39 27.8
10.5-200-1W 10.5 200 5.8 19
10.5-334-1W 10.5 334 9.65 31.8